1、水力喷射器体积小、重量轻、结构紧凑。而效能双比较高,耗电量低于真空泵系统,投资者。
2、操作简单维修方便,不用专职人员管理,由于无机械传动部份,所以噪声低,不需消耗润滑油。
3、可以室外底位安装,占地面积少,可以节省厂房建筑面积与安装费用。
型号规格 | 蒸发量 | 真空度 | 扬程 | 流量 | 配套多级水泵型号 |
L/H | Mpa | M | m3/h | ||
| | | | | |
W-100L | 100 | 0.097(680-720) | 45 | 18 | 50D8×5 |
| | | | | |
W-200L | 200 | 0.097(680-720) | 45 | 18 | 50D8×5 |
| | | | | |
W-300L | 300 | 0.097(680-720) | 45 | 18 | 50D8×5 |
| | | | | |
W-400L | 400 | 0.097(680-720) | 45 | 18 | 50D8×6 |
| | | | | |
W-500L | 500 | 0.097(680-720) | 45 | 32 | 80D12×4 |
| | | | | |
W-600L | 600 | 0.097(680-720) | 45 | 32 | 80D12×4 |
| | | | | |
W-700L | 700 | 0.097(680-720) | 45 | 32 | 80D12×4 |
| | | | | |
W-800L | 800 | 0.097(680-720) | 50 | 32 | 80D12×5 |
| | | | | |
W-900L | 900 | 0.097(680-720) | 50 | 32 | 80D12×5 |
| | | | | |
W-1000L | 1000 | 0.097(680-720) | 50 | 32 | 80D12×5 |
| | | | | |
W-1200L | 1200 | 0.091(680-650) | 50 | 32 | 80D12×6 |
| | | | | |
W-1500L | 1500 | 0.091(680-650) | 50 | 108 | 125D25×2(4BA12) |
| | | | | |
W-1800L | 1800 | 0.091(680-650) | 50 | 108 | 125D25×2 |
| | | | | |
W-2000L | 2000 | 0.091(680-650) | 50 | 108 | 125D25×3 |
| | | | | |
W-3000L | 3000 | 0.091(680-650) | 50 | 108 | 125D25×4(150D30×2) |
备注:以上各种中型号,安装高度>4.5M,器体水压试验0.6MPa无泄漏. |
2、排水管要求垂直而无弯头,如必须曲折时,折角不大于45,常用30,并转折不得多于二次。
3、各接口要求严密,避免泄漏。
4、安装时,用户照扩散管出口管径自配钢管一段作尾管,长充一般应在2米以上,但不伸入循环水池之水中。
5、故障:真空度达不到,原因:安装管道连接渗漏,喷咀堵塞,水泵流量压力不足,真空表失灵。