产品简介

配备多种机能的小型模拟定时器。从短时间到长时间的时间控制。

详细介绍

RoHS規格UL C-UL Recognaized CE Marking

UL/C-UL , CE Approved

Features

1.Multiple functions built in

The operation mode and time range can be switched by using the MODE and RANGE switches on the front panel.

2.Part number consolidation

1.The lineup consists of 64 easy-to-choosemodels.
2.An operation mode fixed type (S1DXM-A) and 4-operation mode switching type (S1DXM-M) are available.

3.Cadmium-free contacts used

To eliminate environmentally harmful chemical substances, relays with cadmium-free contacts are used.

4.Economically priced

1.Prices set to lower costs.
2.Further cost reduction when used with HJ Relay terminal socket.

5.CE marking supporte

UL and C-UL approved.


Operation Mode


1.S1DXM-A multi-range timer


Operation mode
Power ON-delay operationWhen power is turned on, the output contact operates after the set time.
The output contact remains on until the power is turned off.


2.S1DXM-M multi-range timer


Operation mode
Power ON-delay operation
[MODE] switch 1: OFF, switch 2: OFF
. When power is turned on, the output contact operates after the set time.
The output contact remains on until the power is turned off.
Power Flicker OFF start operation
[MODE] switch 1: OFF, switch 2: ON
When the power is turned on, the output contacts repeatedly operate at the set time.
The output contact begins from the off state.
Power Flicker ON start operation
[MODE] switch 1: ON, switch 2: OFF
When power is turned on, the output contact operates repeatedly at the set time.
The output contact outputs at the same time power turns on.
Power One-shot operation
[MODE] switch 1: ON, switch 2: ON
When power is turned on, the output contact performs the on operation at the same time power turns on, only for the set time.


Time range setting


TypeTime scaleTime unitMin.scaleMax.scaleSetting range
S1DXM-A10M type×1×10sm0.0510.05 to 1s0.5 to 10s0.05 to 1m0.5 to 10m
30M typesm0.230.2 to 3s2 to 30s0.2 to 3m2 to 30m
60M typesm0.560.5 to 6s5 to 60s0.5 to 6m5 to 60m
10H typemh0.0510.05 to 1m0.5 to 10m0.05 to 1h0.5 to 10h
S1DXM-M10M type×1×10sm0.0510.05 to 1s0.5 to 10s0.05 to 1m0.5 to 10m
30M typesm0.230.2 to 3s2 to 30s0.2 to 3m2 to 30m
60M typesm0.560.5 to 6s5 to 60s0.5 to 6m5 to 60m
10H typemh0.0510.05 to 1m0.5 to 10m0.05 to 1h0.5 to 10h
*The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h).
Example: When dial reads 1,time scale is X1 and time units is seconds, then it is 1 second.

Operation Mode and Time Range Setting

Operation modePower ON-delayPower Flicker OFF startPower Flicker ON startPower One-shot
Operation mode switch
Time range switch
The time setting can be switched among 4 ranges each for 4 types
for an interval between 0.05 seconds and 10 hours.
1*The product is factory shipped with all settings on the OFF side (left).
2*Do not operate the switches with a sharp-edged object such as a knife blade.
3*The power must be turned off when setting the time range or operation mode. Operating the switches with the power on is a cause of breakdown and malfunction.
4*Use a force of under 5 N to operate the DIP switches when setting the time range and operation mode.

Return to top

Part Number

1.S1DXM-A Multi-range Timer
No MODE Switch, Operation Mode (Fixed): Power ON-delay

Operating voltageTime rangeTimed-out 2 Form CTimed-out 4 Form C
Part NumberPart Number
12V DC0.05s to 10 minS1DXM-A2C10M-DC12VS1DXM-A4C10M-DC12V
0.2 s to 30 minS1DXM-A2C30M-DC12VS1DXM-A4C30M-DC12V
0.5 s to 60 minS1DXM-A2C60M-DC12VS1DXM-A4C60M-DC12V
0.05 min to 10 hrS1DXM-A2C10H-DC12VS1DXM-A4C10H-DC12V
24V DC0.05 s to 10 minS1DXM-A2C10M-DC24VS1DXM-A4C10M-DC24V
0.2 s to 30 minS1DXM-A2C30M-DC24VS1DXM-A4C30M-DC24V
0.5 s to 60 minS1DXM-A2C60M-DC24VS1DXM-A4C60M-DC24V
0.05 min to 10 hrS1DXM-A2C10H-DC24VS1DXM-A4C10H-DC24V
100 to 120V AC0.05 s to 10 minS1DXM-A2C10M-AC120VS1DXM-A4C10M-AC120V
0.2 s to 30 minS1DXM-A2C30M-AC120VS1DXM-A4C30M-AC120V
0.5 s to 60 minS1DXM-A2C60M-AC120VS1DXM-A4C60M-AC120V
0.05 min to 10 hrS1DXM-A2C10H-AC120VS1DXM-A4C10H-AC120V
200 to 220V AC0.05 s to 10 minS1DXM-A2C10M-AC220VS1DXM-A4C10M-AC220V
0.2 s to 30 minS1DXM-A2C30M-AC220VS1DXM-A4C30M-AC220V
0.5 s to 60 minS1DXM-A2C60M-AC220VS1DXM-A4C60M-AC220V
0.05 min to 10 hrS1DXM-A2C10H-AC220VS1DXM-A4C10H-AC220V

2.S1DXM-M Multi-range Timer
With MODE Switch, Operation Mode (Switchable): Power ON-delay, Power Flicker ON Start, Power Flicker OFF Start, Power One-shot

Operating voltageTime rangeTimed-out 2 Form CTimed-out 4 Form C
Part NumberPart Number
12V DC0.05 s to 10 minS1DXM-M2C10M-DC12VS1DXM-M4C10M-DC12V
0.2 s to 30 minS1DXM-M2C30M-DC12VS1DXM-M4C30M-DC12V
0.5 s to 60 minS1DXM-M2C60M-DC12VS1DXM-M4C60M-DC12V
0.05 min to 10 hrS1DXM-M2C10H-DC12VS1DXM-M4C10H-DC12V
24V DC0.05 s to 10 minS1DXM-M2C10M-DC24VS1DXM-M4C10M-DC24V
0.2 s to 30 minS1DXM-M2C30M-DC24VS1DXM-M4C30M-DC24V
0.5 s to 60 minS1DXM-M2C60M-DC24VS1DXM-M4C60M-DC24V
0.05 min to 10 hrS1DXM-M2C10H-DC24VS1DXM-M4C10H-DC24V
100 to 120V AC0.05 s to 10 minS1DXM-M2C10M-AC120VS1DXM-M4C10M-AC120V
0.2 s to 30 minS1DXM-M2C30M-AC120VS1DXM-M4C30M-AC120V
0.5 s to 60 minS1DXM-M2C60M-AC120VS1DXM-M4C60M-AC120V
0.05 min to 10 hrS1DXM-M2C10H-AC120VS1DXM-M4C10H-AC120V
200 to 220V AC0.05 s to 10 minS1DXM-M2C10M-AC220VS1DXM-M4C10M-AC220V
0.2 s to 30 minS1DXM-M2C30M-AC220VS1DXM-M4C30M-AC220V
0.5 s to 60 minS1DXM-M2C60M-AC220VS1DXM-M4C60M-AC220V
0.05 min to 10 hrS1DXM-M2C10H-AC220VS1DXM-M4C10H-AC220V

Return to top

Option

S1DXM-A/M/S1DX Common Options

  • Accesories(mm inch)
  • Socket leaf holding clip for S1DX
  • Terminal socket
  • mm
    inch

Accesories

Mounting frame

ADX18002 / ADX18002 (Titanium-gray) / ADX18006 (Gray) / ADX18007 (Black)

Appearance
Panel cutout dimensions
Board thickness 1 to 3 mm
Note)Make sure the holes area stays as right angles.
Protective cover

ADX18008

Cap block

ADX18011

Cap

ADX18004

Socket

ADX18003

Return to top

Socket Leaf Holding Clip for S1DX

ADX18012AD68002
FigureDimensionsFigureDimensions

Socket lime holding clip for S1DXM-A/M

ADX28005
Dimensions
TypeApplication
Terminal socketADX18012AD68002ADX28005
For HC relayAP3821-availableavailable
AP3827K-available
AP3847K-available
For HJ relayAHJ3821available--
AHJ38211available--
AHJ3848--
AHJ38481--

The triangles indicate that removal will be slightly difficult when installed laterally in succession.

Return to top

Terminal Socket

HC2 slim DIN terminal socket

HC2-SFD-S

HC2 DIN high terminal socket

HC2-SFD-K

HC4 DIN high terminal socket

HC4-SFD-K

HC4 socket

HC4-SS-K

HJ2 terminal socket

HJ2-SFD/HJ2-SFD-S

HJ4 terminal socket

HJ4-SFD/HJ4-SFD-S

HC relay terminal sockets

For general rails
Name / Part No.Terminal socket, HC 2-pin

HC2-SF-K
Dimensions
Note) Only wire springs can be used.(Plate springs cannot be used.)
Terminal layout
Mounting hole dimensions
Panel hole dimensions for side-by-side mounting
Applicable timersS1DX(2c), S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableNot Available
Name / Part No.Terminal socket, HC 2-pin

HC4-HSF-K
Dimensions
Note) Only wire springs can be used.(Plate springs cannot be used.)
Terminal layout
Mounting hole dimensions
Panel hole dimensions for side-by-side mounting
Applicable timersS1DX(2c), S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableAvailable
For DIN rails
Name / Part No.Slim DIN terminal socket,HC2

HC2-SFD-S
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timersS1DX(2c), S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableNot Available

HJ relay terminal sockets

Name / Part No.HJ2h terminal socket

HJ2-SFD
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableNot Available
Name / Part No.HJ2h terminal socket(Finger protect type)

HJ2-SFD-S
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableNot Available
Name / Part No.HJ4 terminal socket

HJ4-SFD
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableAvailable
Name / Part No.HJ4 terminal socket(Finger protect type)

HJ4-SFD-S
Dimensions
Terminal layout
Mounting hole dimensions
Drilling size of panel holes for installing the terminal sockets parallel
Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableAvailable

Sockets

Name / Part No.Socket HC 2-pin 

HC2-SS-K
DimensionsThe difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same.

General tolerance: ±0.5 ±.020
Mounting hole dimensionsThe thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch.
To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below.

Dimensional tolerance of machining: ±0.1 ±.004
Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableNot Available
Name / Part No.Socket, HC 4-pin 

HC4-SS-K
DimensionsThe difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same.

General tolerance: ±0.5 ±.020
Mounting hole dimensionsThe thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch.
To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below.

Dimensional tolerance of machining: ±0.1 ±.004
Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)
AvailableAvailable
*Sockets for PC board
HC2-Socket for PC board: AP3825K
HC4-Socket for PC board: AP3845K

Return to top

Return to top

Dimensions

  • Unit: mm in


  • 1.S1DXM-A
  • 2.S1DXM-M


1.S1DXM-A

General tolerance : ±0.5 ±0.20


Terminal layouts and Wiring diagram
Timed-out 2 Form C type



Terminal layouts and Wiring diagram
Timed-out 4 Form C type


* For the DC operating type, terminal 14 is “+" and terminal 13 is “-".

2.S1DXM-M

General tolerance : ±0.5 ±0.20


Terminal layouts and Wiring diagram
Timed-out 2 Form C type



Terminal layouts and Wiring diagram
Timed-out 4 Form C type


* For the DC operating type, terminal 14 is “+" and terminal 13 is “-".

Return to top

收藏该商铺