Technical Data C3MR
Accuracy class (Combined error) 0.020 % Cn
Maximum capacity Emax 227 | 454 | 1,134 | 2,268 | 5,099 kg
Maximum usable load Eu 200 % Emax
Destructive load Ed > 300 % Emax
Safe side load Elq 100 % Emax
Maximum number of LC intervals nLC 3,000
Minimum LC verification interval vmin = Emax | Y Y 11,500 | 11,000 (Emax = 5,099 kg)
Rated output Cn 2.0 mV/V
Tolerance on rated output Dc < ± 0.1 % Cn
Zero output signal Smin < ± 5.0 % Cn
Creep. during 30 min. dcr < ± 0.0166 % Cn
Temperature effect on Smin TKSmin < ± 0.0122 | < ± 0.0127 (Emax = 5,099 kg) % Cn / 10 K
Temperature effect on C TKC < ± 0.010 % Cn / 10 K
Input impedance RLC 1,100 ± 50 Ω
Output impedance RO 1,000 ± 2 Ω
Insulation impedance (100 V DC) RIS >5 GΩ
Recommended supply voltage Bu 5 … 15 V
Nominal ambient temperature range BT –10 … +40 °C
Usable ambient temperature range BTu –40 ... +80 °C