Accuracy class 0.03 0.02 0.02 % Emax
Maximum capacity Emax s. table s. table s. table
Max. usable load Eu 200 200 200 % Emax
Destructive load Ed > 300 > 300 > 300 % Emax
Minimum LC verification interval vmin = Emax/Y Y - 6,000 11,500
Rated output Cn 2.0 2.0 2.0 mV/V
Tolerance on rated output dc ≤ 0.1 ≤ 0.1 ≤ 0.1 % Cn
Zero output signal Smin ≤ 1.0 ≤ 1.0 ≤ 1.0 % Cn
Creep, during 30min. dcr ≤ 0.025 ≤ 0.016 ≤ 0.016 % Cn
Temperature effect on Smin TKSmin ≤ 0.035 ≤ 0.023 ≤ 0.011 % Cn/10K
Temperature effect on C TKC ≤ 0.014 ≤ 0.010 ≤ 0.010 % Cn/10K
Input impedance RLC 1,100 ± 50 1,100 ± 50 1,100 ± 50 ¥
Output impedance RO 1,000 ± 2 1,000 ± 2 1,000 ± 2 ¥
Insulation impedance RIS > 5,000 > 5,000 > 5,000 M¥
Recommended supply voltage Bu 5… 15 5… 15 5… 15 V
Maximum supply voltage Umax 15 15 15 V
Nominal ambient temperature range BT -10 to +40 -10 to +40 -10 to +40 ° C
Usable ambient temperature range BTu -30 to +70 -30 to +70 -30 to +70 ° C